HP physical server RAID configuration - Smart Storage Administrator CLI
Smart Storage Administrator CLI is the tool for configuring RAID in new model HP physical servers.
Example model : ProLiant DL360 Gen10 (hp_proliant_dl360)Launching : Start -> Windows System -> Smart Storage Administrator CLI
Commands:
ctrl all show
Shows configurations of all controllers
Example array controllers : HPE P408i-a SR Gen10 in Slot 0 (Embedded)
ctrl all show config
Sample output:
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: PEYHC0DRHCP7E7)
Internal Drive Cage at Port 1I, Box 3, OK
Internal Drive Cage at Port 2I, Box 3, OK
Port Name: 1I (Mixed)
Port Name: 2I (Mixed)
Array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (279.37 GB, RAID 1, OK)
physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, OK)
physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK)
Array B (SAS, Unused Space: 0 MB)
logicaldrive 2 (2.18 TB, RAID 5, OK)
physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SAS HDD, 1.2 TB, OK)
physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SAS HDD, 1.2 TB, OK)
physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 1.2 TB, OK)
physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 1.2 TB, OK, spare)
SEP (Vendor ID HPE, Model Smart Adapter) 379 (WWID: 51402EC013D75E58, Port: Unknown)
=>